Boiler fires, radiators stay cold
Water isn't circulating: a seized or failed pump, or a zone valve stuck shut.
Failed circulating pumps and sticking 2-port and 3-port zone valves are some of the most common heating faults. We diagnose them properly and replace only what's actually failed.
Water isn't circulating: a seized or failed pump, or a zone valve stuck shut.
The classic zone valve fault. The motor, microswitch or spindle has failed.
Worn pump bearings, air in the pump, or debris from sludge.
On S-plan systems, one 2-port valve failing leaves that zone cold.
A seized shaft, common after the heating has been off all summer.
Poor circulation means heat can't get away from the boiler fast enough.
Pumps and valves sit in your heating water all year, so the condition of that water decides how long they last.
Since August 2015, standalone circulating pumps must meet an Energy Efficiency Index of 0.23 or better.
Source: Ecodesign Regulation (EC) 641/2009, as amended by 622/2012The ALPHA2 in our photo was drawing just 5 watts. Variable-speed pumps slow down when demand is low.
Source: on-site reading, Grundfos ALPHA2 15-60Older 3-speed pumps typically run at a fixed 45 to 100 watts, whatever the demand.
Source: manufacturers' published ratingsBlack iron-oxide sludge is abrasive and magnetic. It collects in pump rotors and wears them out.
Source: BS 7593 water treatment guidanceA 2-port zone valve (S-plan) simply opens or closes one circuit. A 3-port mid-position valve (Y-plan) directs water to heating, hot water or both from a single valve. When the motor or its internal switch fails, the boiler either never gets the call for heat or the water goes the wrong way, which gives the classic "hot water but no heating" fault.
Worked example: swapping a 60 W fixed-speed pump for a variable-speed one averaging 10 W saves around 100 kWh over 2,000 running hours a year.
We check controls, wiring and valve operation to find exactly what's failed.
Head only, full valve or pump: you'll know which and what it costs.
New parts fitted, air bled out, circulation and controls tested.
If sludge caused it, we'll recommend a clean and filter so it doesn't happen again.
Often, yes. On many 2-port valves the motor head (actuator) unclips from the valve body, so it can be swapped without draining the system. If the valve body or spindle has seized, the whole valve is replaced.
Not always. If there are working isolation valves either side of the pump, it can be changed with minimal water loss. If not, we drain down and fit new valves so next time is easier.
S-plan uses a separate 2-port valve for each zone, such as heating and hot water. Y-plan uses a single 3-port mid-position valve to send water to heating, hot water or both. Both are common. The symptoms of a fault are similar, but the fix is different.
The usual causes are sludge (magnetite) wearing the pump, air in the system, a seized shaft after a summer off, or simple age. If sludge is the cause, cleaning the system and fitting a magnetic filter protects the new pump.
Usually, yes. Since 2015, standalone heating pumps sold in the UK must meet strict efficiency rules. Modern variable-speed pumps adjust to demand and can use a fraction of the electricity of older fixed-speed models.